datacentre audit
Hive Datacentres will undertake a detailed audit of the existing datacentre and will highlight areas of risk to mission critical ICT Services, make recommendations to improve the design and help plan for the future.

Identify Risks
Improve Design
Plan for the future

Equipment layout and room schematics
  • survey and measure room, with all main items of equipment plotted
  • includes all room structure dimensions, and positioning of server and networking cabinets,
  • air-conditioning units, UPS’s, MDF, fire suppression, EPO, electrical distribution and switchgear, lighting and fire suppression.

Datacentre description and report including photographs
  • detailed description including photographs of each element within the room
  • includes server cabs, electrical db schedules and description
  • full report providing detailed findings of our audit including the identification of risk and poor performance

Thermal imaging
  • identify hotspots within cabinets, enabling preventative measures to be undertaken to prevent hardware failure
  • identify hotspots within electrical infrastructure
  • identify other problematic areas, such as hidden heating pipes or air leakage
  • includes full report and recommendations

Temperature and relative humidity logging
  • provide graphical data highlighting ambient conditions within the datacentre including minimum, maximum and average temperature and relative humidity within the room over a period of time.
  • includes full report and recommendations

Temperature and relative humidity probing
  • temperature and relative humidity probing at specific points within the datacentre including cabinet level (at air intake and exhaust) and cooling/return air paths
  • includes full report and recommendations

Airflow readings
  • records airflow readings with the room at grille locations
  • helps ascertain correct airflow patterns and helps identify blockages or poor areas of performance

Power monitoring and logging
  • provides full graphical analysis of power conditions over a set period of time, including load per phase/ph, kW per phase/ph, kVA per phase/ph, summation and total loadings to all above, power factors, snap shot harmonics analysis and waveform captures
  • includes full report and recommendations

Efficiency calculations
  • PUE and other efficiency calculations can be made to assess the efficiency of your facility
  • includes full report and recommendations

Lighting levels
  • lux readings taken at all workable areas to help ensure that there are safe working conditions for personnel.
  • includes full report and recommendations

Network connectivity
  • full testing on your network infrastructure to ensure cabling installations comply with TIA/ISO standards
  • fibre optic testing
  • UTP/STP, CAT6A, CAT6, CAT5e, data link connectivity
  • includes full report and recommendations

Pressure testing
  • integrity testing on the facility to ensure correct pressure is present for effective gaseous suppression deployment
  • includes full report and recommendations

Other services available on request.



Our 5-stage approach offers our clients a complete solution, removing the stresses and difficulties of handling a complex project.